78 research outputs found

    Simulation of seismic events induced by CO2 injection at In Salah, Algeria

    Get PDF
    Date of Acceptance: 18/06/2015 Acknowledgments The authors would like to thank the operators of the In Salah JV and JIP, BP, Statoil and Sonatrach, for providing the data shown in this paper, and for giving permission to publish. Midland Valley Exploration are thanked for the use of their Move software for geomechanical restoration. JPV is a Natural Environment Research Council (NERC) Early Career Research Fellow (Grant NE/I021497/1) and ALS is funded by a NERC Partnership Research Grant (Grant NE/I010904).Peer reviewedPublisher PD

    Basin-scale multi-decadal analysis of hydraulic fracturing and seismicity in western Canada shows non-recurrence of induced runaway fault rupture

    Get PDF
    Hydraulic fracturing (HF) is a reservoir stimulation technique that has been widely deployed in recent years to increase the productivity of light oil and/or natural gas from organic-rich, low-permeability formations. Although the process of fracturing a rock typically results in microseismic events of magnitude  0.5. Most previous studies of induced earthquakes have been limited to a single operation and/or seismicity sequence. To better understand the observed variability of the seismic response to HF stimulations at a basin scale, we compiled HF data for all unconventional wells hydraulic fractured in the WCSB between 2000 and 2020, together with the seismicity reported during the same period. We grouped these observations into bins measuring 0.2° in longitude and 0.1° in latitude, or approximately 13 by 11 km. We identified 14 areas where large magnitude events resulted in high S(EFF) values, implying runaway rupture had taken place. However, we find that in these areas, sustained fluid injection did not lead to persistent high S(EFF) values. Instead, as injection continued, S(EFF) values returned to values less than 0.5. This suggests that there is a limited budget of tectonic strain energy available to generate runaway rupture events: once this is released, event magnitudes decrease even if high volume injection persists

    The microseismic response at the In Salah Carbon Capture and Storage (CCS) site

    Get PDF
    AbstractIn 2004, injection of carbon dioxide (CO2) to be stored at depth began at the In Salah Carbon Capture and Storage (CCS) site and a pilot microseismic monitoring array was installed in 2009. The In Salah project presents an unusual dataset since it is the first major non-Enhanced Oil Recovery (EOR) CCS project to be monitored for microseismicity. This paper outlines an extensive seismological study using a range of techniques, relying mainly on data from a single three-component geophone. Important information is derived from the data, such as event locations, event magnitudes and fracture characteristics, that could be used in real-time to regulate the geomechanical response of a site to CO2 injection. The event rate closely follows the CO2 injection rate, with a total of 9506 seismic events detected. The locations for a carefully selected subset of events are estimated to occur at or below the injection interval, thereby ruling out fault or fracture activation caused by CO2 migration at shallow depths. A very small number of events (11) with less well-constrained locations may have occurred above the injection interval. However, there is no microseismic evidence that these events are correlated with CO2 injection and we suggest they are caused by stress transfer rather than CO2 migration into the caprock. The observed maximum moment magnitude, Mw=1.7, is consistent with estimated fracture dimensions at the injection depth. Fracture orientation estimated using shear-wave splitting analysis is approximately NW-SE, in agreement with fracture orientations inferred from logging data. During periods of high injection rates the degree of anisotropy increases slightly and then falls back to original values when injection rates fall. This implies the CO2 is opening pre-existing fractures which then close as pressure decreases.This an important proof-of-concept study that proves the value of microseismic monitoring of CCS projects, even with a limited array. We thus recommend that microseismic monitoring arrays are installed prior to CO2 injection at future CCS sites to enhance our understanding by making baseline and comparative studies possible. This would also provide real-time monitoring of the geomechanical response to injection, allowing operators to modify injection parameters and to help ensure the safe operation of a project
    • …
    corecore